Journal DOI 10.68956/journal.human-performance-futures

Creative Commons source reading · Gait, running and locomotion

Wearable Sensor–Derived Gait Parameters Across Self-Reported Physical Activity Levels in Individuals With Knee Osteoarthritis and Healthy Controls: Pilot Cross-Sectional Validation Study

Charles Amoatey Odonkor; Siri Bohacek; Salman Hirani; Wei Zhang; Amir Muaremi; Heike Leutheuser; Matthew Smuck

Originally published in JMIR Form Res · 2026-06-03

From the article

Selected source text. JournalOS removes markup and shortens excerpts where indicated. The full article provides the complete context.

Abstract

AbstractBackgroundWearable inertial measurement units (IMUs) offer scalable, objective gait assessment, but detailed stride-level validation against motion capture and their ability to reflect physical activity (PA)–related gait differences in knee osteoarthritis (KOA) remain incompletely characterized.ObjectiveThis study aimed to evaluate the technical validity of foot-mounted IMU–derived gait parameters compared with optical motion capture in individuals with KOA and healthy controls. As a secondary exploratory aim, we assessed whether IMU-derived gait parameters differed across self-reported PA levels.MethodsIn this pilot cross-sectional validation study, 20 participants (KOA: n=10, 50%; healthy controls: n=10, 50%) completed 3 standardized walking conditions (self-paced, fast-paced, and endurance-equivalent). IMU-derived gait…

Principal Findings

This pilot study evaluated the feasibility and technical validity of foot-mounted IMUs for quantifying spatiotemporal gait parameters in adults with KOA and healthy controls. Motion capture validation demonstrated strong agreement between IMU-derived and reference measures across standardized walking conditions. Agreement was evaluated using multiple complementary metrics, including ICCs, absolute error measures, and Bland-Altman analyses. Across ≥5000 strides pooled at the stride level, IMU-derived gait speed, stride length, and cadence showed high concordance with motion capture, minimal systematic bias, and narrow limits of agreement. These findings support the technical validity of the IMU-based gait algorithm across both healthy and pathological gait patterns. In addition to validation, this study assessed the feasibility of…

Conclusions

In this pilot cross-sectional validation study, foot-mounted wearable IMUs demonstrated strong agreement with optical motion capture across standardized walking conditions, with high ICCs and minimal systematic bias. These findings support the technical validity and feasibility of stride-level gait assessment using foot-mounted wearable IMUs in adults with KOA. Exploratory analyses suggested directional differences in pace- and rhythm-domain gait parameters across self-reported PA levels. However, given the small sample size, cross-sectional design, and absence of multiplicity adjustment, these associations should be interpreted as hypothesis-generating. Larger, longitudinal investigations are needed to confirm these preliminary signals and to determine how wearable-derived gait parameters relate to disease severity, PA behavior, and…

Editorial reading guide

  • How was movement measured, and what error or calibration information is reported?
  • Can the finding transfer from the tested task and population to the intended sport setting?