Creative Commons source reading · Gait, running and locomotion
Treadmill-based assessment of running-specific prostheses in steady and accelerated running: a case study with a Paralympic medalist
Samira G. Breban; Giuseppe Marcolin; Roberto Di Marco; Andrea G. Cutti; Gian Luca Migliore; Nicola Petrone
Originally published in Front Sports Act Living · 2026-06-10
From the article
Selected source text. JournalOS removes markup and shortens excerpts where indicated. The full article provides the complete context.
Abstract
Running-specific prostheses (RSPs) enable individuals with lower-limb amputation to compete in Paralympic running disciplines. In a high-level sports context, optimal RSP tuning based on biomechanical parameters is essential to enhance running performance. Although on-track assessment is considered the gold standard, its high financial and logistical demands make treadmill-based setups valuable alternatives. Therefore, this single-case study aimed to present a method for assessing steady-state running (SSR) and resisted acceleration running (RAR) in an amputee athlete, comparing different RSP alignments. The experimental setup combined a commercial treadmill mounted over four dynamometric platforms with an eight-camera motion capture system, enabling the kinetic, kinematic, and spatiotemporal assessment of different RSP…
Results
Results for SSR are presented as mean and standard deviation of the six strides analyzed for AL and UL, separately. Conversely, for RAR, results of INIT, MID, and FIN steps are presented as single values. In RAR, the maximum speed achieved was 3 m/s for both alignments.
Kinetics results
In SSR, the GRFV peak was 9% higher in ST15° (4.43 BW) than ST9° (4.06 BW) for UL, but 14% lower in AL (2.61 BW) compared with UL (3.07 BW). As for GRFAP, during SSR, UL exhibited a breaking GRFAP (−0.63 BW with ST9° and −0.70 BW with ST15°) greater than AL (−0.40 BW with ST9° and −0.23 BW with ST15°). Conversely, the propulsive GRFAP values were similar for both alignments (UL: 0.48 BW with ST9° and 0.44 BW with ST15°; AL: 0.44 BW with ST9° and 0.45 with ST15°). Figure 2 illustrates the described results. Regarding SSR impulses (Figure 3), UL showed greater IHb than AL, with higher values in ST15° compared with ST9°. Moreover, UL generated smaller IHp than AL with both ST9° (−12%) and ST15° (−25%). Consequently, IHn assumed negative values for UL and positive values for AL. Impulse values shown in the figure were scaled by a factor…
Editorial reading guide
- How was movement measured, and what error or calibration information is reported?
- Can the finding transfer from the tested task and population to the intended sport setting?