The Concurrent Validity and Test–Retest Reliability of a Smartphone-Based Markerless System

Nicholson KF; Duane JJ; Carter W; Fernandez G; Wolf J; Butler RJ; Bullock GS

Originally published in Sensors (Basel) · 2026-06-21

From the article

Selected source text. JournalOS removes markup and shortens excerpts where indicated. The full article provides the complete context.

Abstract

AbstractIncreasing the accessibility and portability of precise biomechanical data to sports scientists can assist in making data-driven decisions. The purpose of this study was: (1) Assess the concurrent and convergence validity of discrete and continuous waveform biomechanics of a smartphone-based markerless system. (2) Assess test–retest reliability of the smartphone-based markerless system. Movements were recorded simultaneously with two iPhones using Uplift Labs computer vision software and with Qualisys, a 12-camera marker-based motion capture system. Each participant performed two evaluations, one week apart, consisting of two countermovement jumps. Nested Bland–Altman limits of agreement (LOA), mixed-effect linear regressions, and intraclass correlation coefficients (ICC) were calculated. Twenty participants were included…

3. Results

A total of 20 participants were included [Age: 24.7 (6.6) years. Height: 178.3 (4.3) cm. Mass: 86.5 (12.4) kg. Dominant Arm (Right): 17 (85%)]. Collection totaled seventy-two CMJ trials (Table 1).

4. Discussion

This study examined the concurrent and convergence validity and test–retest reliability of the countermovement jump between the Uplift two smartphone-based markerless biomechanical system and the Qualisys marker-based 3D motion analysis system. Uplift’s performance in tracking maximum CMJ flexion angles was inconsistent across different segment angles. The CMJ LOA’s were not within the a priori-defined limits. However, the CMJ demonstrated similar test–retest reliability between biomechanical systems, but most joint angles did not meet the acceptable test–retest thresholds. Limits of agreement for CMJ were beyond the a priori acceptable thresholds of ±2°. This supports previous work observing that portable markerless devices have fallen short of acceptable concurrent validity when compared to marker-based optical systems [19,34]. The…