Abstract
AbstractIntroductionIndividuals with bilateral upper limb loss face substantial barriers to independence and recreational participation. Adaptive sports can enhance psychological and physical well-being, yet few prosthetic devices are specifically designed or biomechanically evaluated for use in adaptive sports. Golf demands coordinated motion, stability, and dynamic control, often exceeding the capabilities of most traditional prostheses. Custom prosthetic solutions remain essential for enabling meaningful participation. This study aimed to design, fabricate, and evaluate a custom golf prosthesis for a veteran with bilateral upper limb loss, with primary emphasis on functional feasibility and characterization of swing biomechanics.MethodsA custom carbon-fiber monolimb prosthesis with a hinged clamshell distal end was developed to…
Results
A summary of all measured biomechanical variables, including participant values and corresponding normative ranges, is provided in Table 1. Key findings for body alignment, downswing kinematics, X-factor rotation, and weight-shift patterns are described below.
Discussion
This study aimed to design, fabricate, and evaluate a golf-specific prosthesis for a veteran with bilateral upper limb loss, with a primary focus on feasibility and functional participation. The results demonstrated that the prosthesis enabled independent club attachment, a coordinated two-armed swing, and successful engagement in adaptive golf, addressing an unmet need in a population that faces substantial barriers to sport participation. Biomechanical analysis revealed reduced angular velocities, lower clubhead speed, limited X-factor rotation, and neutral wrist motion relative to normative values (26); however, these findings were intended to characterize movement strategies and identify design-relevant constraints rather than to evaluate athletic performance. Together, the results illustrate how a clinically feasible,…
Editorial reading guide
- How was movement measured, and what error or calibration information is reported?