Creative Commons source reading · Epilepsy and seizure classification
EEG source connectivity to localize the seizure onset zone in patients with drug resistant epilepsy.
Willeke Staljanssens; Gregor Strobbe; Roel Van Holen; Vincent Keereman; Stefanie Gadeyne; Evelien Carrette; Alfred Meurs; Francesca Pittau; Shahan Momjian; Margitta Seeck; Paul Boon; Stefaan Vandenberghe; Serge Vulliemoz; Kristl Vonck; Pieter van Mierlo
Originally published in NeuroImage. Clinical · 2017-09-14
From the article
Selected source text. JournalOS removes markup and shortens excerpts where indicated. The full article provides the complete context.
Abstract
Electrical source imaging (ESI) from interictal scalp EEG is increasingly validated and used as a valuable tool in the presurgical evaluation of epilepsy as a reflection of the irritative zone. ESI of ictal scalp EEG to localize the seizure onset zone (SOZ) remains challenging. We investigated the value of an approach for ictal imaging using ESI and functional connectivity analysis (FC). Ictal scalp EEG from 111 seizures in 27 patients who had Engel class I outcome at least 1 year following resective surgery was analyzed. For every seizure, an artifact-free epoch close to the seizure onset was selected and ESI using LORETA was applied. In addition, the reconstructed sources underwent FC using the spectrum-weighted Adaptive Directed Transfer Function. This resulted in the estimation of the SOZ in two ways: (i) the source with maximal power after ESI, (ii) the source with the strongest outgoing connections after combined ESI and FC. Next, we calculated the distance between the estimated SOZ and the border of the resected zone (RZ) for both approaches and called this the localization error ((i) LE pow and (ii) LE conn respectively).
Conclusion
We showed that it is possible to estimate the SOZ from clinical or low-density scalp EEG with high accuracy using ESI and subsequent functional connectivity analysis. Moreover, the proposed method is non-invasive and requires, after initial epoch and frequency selection, minimal user-dependent input. Altogether, the method could serve as a useful tool for SOZ localization in the presurgical evaluation of epilepsy. Larger studies are warranted, notably with more extratemporal epilepsies and localization correlation with a range of different outcomes.
Editorial reading guide
- Which patient population and reference standard did the authors use?
- Was the finding validated in a separate cohort, and how might patient selection affect it?