Abstract
Background In the evaluation of Stereo-Electroencephalography (SEEG) signals, the physicist's workflow involves several operations, including determining the position of individual electrode contacts in terms of both relationship to grey or white matter and location in specific brain regions. These operations are (i) generally carried out manually by experts with limited computer support, (ii) hugely time consuming, and (iii) often inaccurate, incomplete, and prone to errors. Results In this paper we present SEEG Assistant, a set of tools integrated in a single 3DSlicer extension, which aims to assist neurosurgeons in the analysis of post-implant structural data and hence aid the neurophysiologist in the interpretation of SEEG data. SEEG Assistant consists of (i) a module to localize the electrode contact positions using imaging data from a thresholded post-implant CT, (ii) a module to determine the most probable cerebral location of the recorded activity, and (iii) a module to compute the Grey Matter Proximity Index, i.e. the distance of each contact from the cerebral cortex, in order to discriminate between white and grey matter location of contacts.
Results
In this work we present SEEG Assistant, a 3DSlicer extension designed to assist neurosurgeons in post-implant image processing of SEEG implants. The proposed extension is composed of three modules that aim to (i) localize the position, (ii) estimate the most probable cortical sources of the recorded signals, and (iii) extract GMPI and volumetric labelling to enable later classification of white-grey matter contacts.
Discussion
We introduce a set of tools to aid the post-surgery assessment of SEEG implants. The provided tools are built as an extension called SEEGA and are integrated in 3D Slicer exploiting its advanced medical imaging processing capabilities. Our set of tools enrich the collection of extensions of 3D Slicer making it a perfect tool for surgical planning and post-surgery assessment. We preferred creating an extension to an existing software rather than a new stand-alone all-in-one tool, to allow users to define their preferred set of pre-processing steps.
Conclusions
In this work we present SEEG Assistant, a piece of software specifically designed to support neurosurgeons in post-seeg implant processing. We exploit an open-source paradigm, easily accessible and integrated interface connected to 3DSlicer. Our tool significantly eases the SEEG post-implant analysis by drastically reducing the time required for segmentation and localization. Our analyses show that automatic segmentation is significantly more accurate than manually extracted coordinates.
Editorial reading guide
- How were patients or cases selected, and what did the authors use as a comparator?
- Which outcomes, complications and follow-up intervals determine how far the findings apply?